1. Working platforms, gangways and stairways shall-- o (a) be so constructed that no part thereof can sag unduly or unequally; o (b) be so constructed and maintained, having regard to the prevailing conditions, as to reduce as far as practicable risks of persons tripping or slipping; and o (c) be kept free from any unnecessary obstruction. 2. In the case of working platforms, gangways, working places and stairways at a height exceeding that to be prescribed by national laws or regulations-- o (a) every working platform and every gangway shall be closely boarded unless other adequate measures are taken to ensure safety; o (b) every working platform and gangway shall have adequate width; and o (c) every working platform, gangway, working place and stairway shall be suitably fenced.